Products

TIVA

Our TIVA sets have been specially developed for use with Intravenous Anaesthesia. The product range consists of sets with different combinations of 3-way stopcocks, check valves and/or anti-siphon valve which are assembled complete with infusion pump tubes and, if desired, infusion device. The same options are available for solutions where the 3-way stopcocks are replaced with tube combinations (“octopus sets”). We offer a large number of ready-made solutions, pre-glued or unglued, depending on how much help you want in advance or how much you want to be able to connect the system yourself or have the option of separating the components.

Mediplast Srl
Infusion Line TIVA 3 x 3-way stopcock with swivel, 3 x one-way valve, needle-free connector, 10cm extension, 2 x syringe pump tube, PVC-free
• Colour coded 3-way stopcocks to support identification of the infusion line
• Swivel - a design that allows the stopcock to rotate
• Syringe pump tube Ø 1 x 2mm (IDxOD)
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
Mediplast Srl
Infusion Set TIVA 180cm, non-vented with one-way valve, 2 x 3-way stopcock + 15cm extension, DEHP-free PVC
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm
• Colour coded 3-way stopcocks to support identification of the infusion line
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, non-vented with one-way valve, 2 x 3-way stopcock with one-way valve + 10cm extension with needle-free connector, 2 x 150cm syringe pump tube, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm
• Colour coded 3-way stopcocks to support identification of the infusion line
• Syringe pump tube Ø 1 x 2mm (IDxOD)
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, non-vented with one-way valve, 2 x 3-way stopcock with one-way valve + 15cm extension, 2 x 150cm syringe pump tube, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm
• Colour coded 3-way stopcocks to support identification of the infusion line
• Syringe pump tube Ø 1 x 2mm (IDxOD)
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, non-vented with one-way valve, 2 x 3-way stopcock with one-way valve + 15cm extension, 2 x 200cm syringe pump tube, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm
• Colour coded 3-way stopcocks to support identification of the infusion line
• Syringe pump tube Ø 1 x 2mm (IDxOD)
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, non-vented with one-way valve, 2 x 3-way stopcock with one-way valve + 15cm extension, 2 x syringe pump tube, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm
• Colour coded 3-way stopcocks to support identification of the infusion line
• Syringe pump tube Ø 1 x 2mm (IDxOD)
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, non-vented with one-way valve, 3 x 3-way stopcock with one-way valve + 15cm extension, 3 x 150cm syringe pump tube, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm
• Colour coded 3-way stopcocks to support identification of the infusion line
• Syringe pump tube Ø 1 x 2mm (IDxOD)
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, non-vented with one-way valve, 3 x 3-way stopcock with one-way valve + 15cm extension, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm
• Colour coded 3-way stopcocks to support identification of the infusion line
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, vented with Air-Guard and one-way valve, 3 x 3-way stopcock + 100cm extension with one-way valve + 15cm extension, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm and air filter of 0,2μm
• Air-Guard prevents air passing into the tube when the infusion has run out
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, vented with Air-Guard, one-way valve, 2 x 3-way stopcock + 15cm extension and one-way valve, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm and air filter of 0,2μm
• Air-Guard prevents air passing into the tube when the infusion has run out
• Colour coded 3-way stopcocks to support identification of the infusion line
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, vented with Air-Guard, one-way valve, 3 x 3-way stopcock + 100cm extension with one-way valve + 15cm extension, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm and air filter of 0,2μm
• Air-Guard prevents air passing into the tube when the infusion has run out
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, vented with Air, Guard and one-way valve, 2 x 3-way stopcock with one-way valve + 12cm extension, 2 x syringe pump tube, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm and air filter of 0,2μm
• Air-Guard prevents air passing into the tube when the infusion has run out
• Colour coded 3-way stopcocks to support identification of the infusion line
• Syringe pump tube Ø 1 x 2mm (IDxOD)
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, vented with Air, Guard and one-way valve, 3 x 3-way stopcock + 10cm extension with one-way valve, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm and air filter of 0,2μm
• Air-Guard prevents air passing into the tube when the infusion has run out
• Colour coded 3-way stopcocks to support identification of the infusion line
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, vented with one-way valve, 2 x 3-way stopcock with one-way valve + 10cm extension, needle-free connector, 2 x 200cm syringe pump tube, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm and air filter of 0,2μm
• Syringe pump tube Ø 1 x 2mm (IDxOD)
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, vented with one-way valve, 2 x 3-way stopcock with one-way valve + 15cm extension, 2 x 150cm syringe pump tube, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm and air filter
• Colour coded 3-way stopcocks to support identification of the infusion line
• Syringe pump tube Ø 1 x 2mm (IDxOD)
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, vented with one-way valve, 2 x 3-way stopcock with one-way valve + 15cm extension, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm and air filter of 0,2μm
• Colour coded 3-way stopcocks to support identification of the infusion line
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, vented with one-way valve, 2 x 3-way stopcock with one-way valve + extension, 2 x syringe pump tube, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm and air filter of 0,2μm
• Colour coded 3-way stopcocks to support identification of the infusion line
• Syringe pump tube Ø 1 x 2mm (IDxOD)
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, vented with one-way valve, 2 x 3-way stopcock with one-way valve, 10cm extension, 2 x 200cm syringe pump tube, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm and air filter of 0,2μm
• Colour coded 3-way stopcocks to support identification of the infusion line
• Syringe pump tube Ø 1 x 2mm (IDxOD)
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, vented with one-way valve, 2 x 3-way stopcock with one-way valve, swivel and 5cm extension, 2 x 150cm syringe pump tube, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm and air filter of 0,2μm
• Colour coded 3-way stopcocks to support identification of the infusion line
• Swivel - a design that allows the stopcock to rotate
• Syringe pump tube Ø 1 x 2mm (IDxOD)
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, vented with one-way valve, 3 x 3-way stopcock + 15cm extension, 3 x one-way valve, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm and air filter of 0,2μm
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, vented with one-way valve, 3 x 3-way stopcock + 5cm extension with one-way valve, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm and air filter of 0,2μm
• Colour coded 3-way stopcocks to support identification of the infusion line
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, vented with one-way valve, 3 x 3-way stopcock + extension, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm and air filter of 0,2μm
• Colour coded 3-way stopcocks to support identification of the infusion line
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, vented with one-way valve, 3 x 3-way stopcock with one-way valve + 15cm extension, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm and air filter of 0,2μm
• Colour coded 3-way stopcocks to support identification of the infusion line
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 180cm, vented, 2 x 3-way stopcock with one-way valve, 12cm extension, 2 x 150cm syringe pump tube, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm and air filter of 0,2μm
• Colour coded 3-way stopcocks to support identification of the infusion line
• Syringe pump tube Ø 1 x 2mm (IDxOD)
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 200cm, vented with Air-Guard, one-way valve, 3-way stopcock + 15cm extension, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm and air filter of 0,2μm
• Air-Guard prevents air passing into the tube when the infusion has run out
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Mediplast Srl
Infusion Set TIVA 220cm, vented with Air-Guard and one-way valve, 3 x 3-way stopcock + 15cm extension, PVC-free
• Roller clamp intended to ensure consistent and safe infusion rate
• Spike without silicone to enable safe connection to infusion bag/bottle
• Liquid filter of 15μm and air filter of 0,2μm
• Air-Guard prevents air passing into the tube when the infusion has run out
• Flowstop with hydrophobic filter designed to simplify priming and reduce the risk of leakage and contamination
• Self-ejecting rotating luer-lock
• MRI compatible
• 20 drp aqua dest = 1ml
Scroll to top